Using the PC Card Erase Utility
To completely erase a Database PC Card (P/N 85880):
This function will completely erase all the databases in a Database
PC Card (P/N 85880).
1. Insert the PC Card into the CPU.
2. Be sure the CPU mode switch is set to RUN.
3. Enter the programming mode.
4. Dial 9908 + HOLD.
You see: ERASE ALL (Y/N).
5. Press Y + HOLD to continue.
You see ABORT (Y/N).
6. Press N + HOLD to continue.
To abort this procedure and return to step 4, press Y + HOLD
instead.
7. When the PC card is completely erased, you see: PCCARD ERASED!
8. Press CONF twice to exit.
Restoring Site Data
To use the PC Card to restore site data:
1. Insert the PC Card into the CPU.
2. Be sure the CPU mode switch is set to RUN.
3. Enter the programming mode.
ICM + #*#* + 372000 + HOLD
4. Dial 9907 + HOLD.
You see: START?
5. Dial Y + HOLD.
You see the name and date of the first database stored. If no data-
bases are stored, you see:
9907: DB00
(empty)
6. Press VOL
select the one you want to restore.
U Slot software 02.00.01 and above have 16 data base addresses:
DB 00 to DB 15
7. When the database you want to restore displays, press HOLD.
The PC Card Active LED is on during restore.
You automatically exit programming when the backup completes.
DS2000 System Installation
or VOL
to scroll through the database addresses and
DS1000/2000 Workbook