Download Print this page

NEC DS1000 Correspondence Course Workbook page 22

Hide thumbs Also See for DS1000:

Advertisement

DS1000/2000 Correspondence Course
System Configuration
If upgrading from a software version prior to 02.02.14:
• Use 9803 - Initialize Distinctive Ringing to initialize Distinctive Ringing. Following
initialization, you must reset the system or unplug and then replug each telephone.
Refer to the DS1000/2000 Software Manual or the Release Notes on your System
Document CD for more.
• Use 9804 - Initialize Caller ID Log Utility to initialize (clear) your Caller ID logs.
Refer to the DS1000/2000 Software Manual or the Release Notes on your System
Document CD for more.
• Be sure your system's hardware configuration does not exceed the System Load
Factor. See DS1000 System Load Factor Calculations on page 20 and DS2000
System Load Factor Calculations on page 25 for more.
.When installing telephones and other station devices:
• Digital station ports (300-315 in DS1000, on installed and programmed PCBs in
DS2000) automatically detect the type of connected device when the keyset, 2-OPX
Module (both ports) or Digital Door Box is plugged in. It is no longer necessary to
individually set circuit types 1801 - Extension Circuit Type.
• For additional resources, visit our Technical Support site on the web at
208.141.100.36/ds2000.
This software uses the following hardware default assignments:
• Slot CN1 = 16DSTU PCB (Extensions 300-315).
• Slot CN2-CN8 = Undefined.
When installing PCBs:
• After plugging in your PCBs and powering up the system, use 9902 -Slot Control to
enable the installed PCBs. See Using Program 9902 in DS2000 to Add or Delete
PCBs on page 133 for more.
22
DS1000/2000 Workbook
Upgrading Software
DS2000 Installation Notes
NEC America

Advertisement

loading

This manual is also suitable for:

Ds2000