DS1000/2000 Correspondence Course
Reprogram Slot Configuration
1. Program an empty slot for your required PCB using the following steps.
When you're programming (adding) an empty slot, you may see the fol-
lowing error messages:
9902 Error Message
ERR! NO SLOT CHANGE
SLOT 1 IS FIXED!
SLOT IN USE!
Enter the programming mode and dial
a.
9902: Slot Control.
Press
b.
HOLD
want to program (2-8).
Press
c.
HOLD
Press
+
d.
N
HOLD
enter a new PCB assignment.
Press
, then
e.
ICM
cuit types for the slot selected.
When the circuit type you want displays, press
f.
.
EXTENSION
Enter the first extension number for the PCB. Refer to the configuration
g.
chart you completed above. (For example, if you have a second DSTU in
slot 2, and you want the extension numbers to flow consecutively from
slot 1, enter 316.)
If you make an entry mistake, use LND to backspace over (erase)
the incorrect entry and then enter the correct digits.
Press
h.
HOLD
Press
i.
HOLD
program (2-8), or press
Verify Your Slot Entries
Enter the programming mode and dial
1.
9902: Slot Control.
Press
then
2.
HOLD
check (1-8).
DS2000 System Installation
Occurs if you are trying to assign an extension
range that already exists. Also occurs if your
assignment will exceed the system maximums
(e.g., assigning a 7th 16DSTU).
You are trying to change the assignment for slot 1,
which is fixed for a 16DSTU PCB.
You have attempted to delete the slot that supports
the extension from which you are programming.
then
or
VOL Up
VOL Down
. You see
ADD CARD (Y/N)
to return to step 'b' without adding a PCB, or press
or
VOL Up
VOL Down
. You see
SLOT CONFIG CHANGED!
twice +
or
VOL Up
VOL Down
to exit program 9902.
CONF
or
VOL Up
VOL Down
Description
+
to enter program
9902
HOLD
until you select the empty slot you
.
to scroll through the available cir-
. You see:
HOLD
to select another slot to
+
to enter program
9902
HOLD
until you select the slot you want to
DS1000/2000 Workbook
to
Y
FIRST
85

Advertisement

loading

This manual is also suitable for:

Ds2000