Electrical installation
4.5 Connections
1. Route the DRIVE-CLiQ/signal cable to the Control Unit into the cabinet from the bottom
left.
2. Use cable ties to secure the cable at suitable points.
3. Route the cable further in the cabinet to the upper side of the Control Unit. When doing
so, route the cable in a similar manner to the standard cables that have already been
installed in the cabinet.
4. Use cable ties to secure the cable at suitable points.
5. Connect DRIVE-CLiQ/signal cable to the Control Unit.
6. Route the DRIVE-CLiQ/signal cable to the Motor Module from the bottom left into the
cabinet.
7. Use cable ties to secure the cable at suitable points.
8. Route the cable further in the cabinet to the upper side of the Motor Module. When doing
so, route the cable in a similar manner to the standard cables that have already been
installed in the cabinet.
9. Use cable ties to secure the cable at suitable points.
10. Connect the signal cable at terminal block -X9.
11. Route the DRIVE-CLiQ cable through the cable bushing from the top into the Motor
Module, continue to the DRIVE-CLiQ connection -X400, -X401, -X402 and connect there.