Siemens SINAMICS S120 Manual page 286

Cabinet modules liquid-cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Options
9.3 G20, CBC10 Communication Board
X451 CAN bus interface
CAN bus interface -X451 features the following socket assignments:
Table 9- 1
Connector type: 9-pin Sub-D socket
NOTICE
Destruction of the CAN interface due to the wrong connector
If PROFIBUS connectors are connected to CAN bus interfaces during operation, this may
lead to the CAN interfaces being destroyed.
• Do not connect PROFIBUS connectors to CAN bus interfaces.
X452 CAN bus interface
CAN bus interface -X452 features the following socket assignments:
Table 9- 2
Connector type: 9-pin SUB D connector (pins)
286
CAN bus interface X451
Pin
Designation
1
Reserved
2
CAN_L
3
CAN_GND
4
Reserved
5
CAN_SHLD
6
GND
7
CAN_H
8
Reserved
9
Reserved
CAN BUS interface X452
Pin
Designation
1
Reserved
2
CAN_L
3
CAN_GND
4
Reserved
5
CAN_SHLD
6
GND
7
CAN_H
8
Reserved
9
Reserved
Technical data
CAN signal (dominant low)
CAN ground
Optional shield
CAN ground
CAN signal
Technical data
CAN signal (dominant low)
CAN ground
Optional shield
CAN ground
CAN signal