Also, the other information can be seen on the display. All reminders and their description are
specified in the following table:
Information
Acoustic
displayed
alarm
Variable
Variable
Interrupted
Interrupted
The menu is divided into two sections: the operational menu (the unit in the ON mode) and the
service menu (unit in the OFF mode).
Operational Menu (Controller in ON Mode, see also sec.13.3.3 on page 120)
Function name
Setting of heating
temperature
Setting of temperature
hysteresis
* Depending on the maximum heating temperature programmed in the controller.
** Factory settings are only the proposals for a setting. All the values depend on the size of heaters, the
capacity of the tank, user requirements etc.
Service Menu (Controller in OFF Mode, see also sec. 13.3.4 on page 120)
Function name
Setting of heating
detection
Alarm diode
Description
Flashing
Lack or failure of the sensor. Alarm switches off automatically
after repair of the failure.
Flashing
Exceeding of the maximum temperature (75 °C, 95 °C,
110 °C) (Protect). Alarm is switched off after manual deleting
(entering the off switching mode).
Flashing
Detection of lack of water (No Liquid). Alarm is switched off
after manual deleting (entering the off switching mode).
Flashing
Detection of lack of heating (No Heating). Alarm is switched off
after manual deleting (entering the off switching mode).
Input of the external control EXT opened.
Controller stops the function of heating.
Parameter
Setting ranges
15–160 °C*
1–10 °C*
Parameter
Setting ranges
0 and 1
PAW-VP•LDHW - Technical Manual – 2019-11
Factory setting
50 °C**
°C**
Factory setting
1