System Paci And Paw-Vp 380L Cooling/Heating - Panasonic PAW-VP1000LDHW Technical Manual

Air-to-water heat pump systems, domestic hot water system for r410a and r32 use
Hide thumbs Also See for PAW-VP1000LDHW:
Table of Contents

Advertisement

System drawings
6.7
6
88

System PACi and PAW-VP 380L Cooling/Heating

L Room heating (and cooling) system with
multiple outdoor units and 380L tanks
4
9
4
5
(Field supplied) accessories
1. Expansion tank (field supplied)
2. Water pipe return/turn tank 35 mm (field
supplied)
3. TA valve control valve water flow DN35
(field supplied)
4. Water pipe main return/turn 52 mm (field
supplied)
5. Max water flow 8000 L/h
3
8 7
2
2
6
1
6. TA sensor
7. E1 sensor
8. E3 sensor
9. Air separator (field supplied)
10. PAW-VP-RTC5B-PAC controller
11. (Fig not shown) Immersion heater kit
3
J
8 7
6
6 kW 230/400 V single or 3 phase version
PAW-VP•LDHW - Technical Manual – 2019-11
J

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Paw-vp750ldhwPaw-vp500ldhwPaw-vp200ldhwPaw-vp380l

Table of Contents