System drawings
6.5
6
86
System U-16MF3E8 with DHW
Mixed System with DHW
tank and indoor units,
with circulation pipe and
temperature control system
2
City Water in
1
3
(Field supplied) accessories
1. Pressure control valve if inlet city water is
more then 6 bar (field supplied)
2. Strainer (field supplied)
3. Expansion tank if check valve or pressure
control valve is mounted (field supplied)
4. Circulation water pump (e.g. Grundfos
comfort UP 15–14 BA PM, field supplied),
if needed
5. Safety valve 6 or 9.5 bar (field supplied)
6. Temperature control valve (field supplied)
M
L
8
K
9
J
7
7. Water pipe inlet/outlet VP1000L/750
(35 mm) VP500L/200 (22 mm)
8. Expansion valve PAW-VP-VALV-280/-160
(field supplied)
9. TA sensor
10. E2 sensor
11. E1 sensor
12. E3 sensor
13. Solenoid valve kit (field supplied)
14. PAW-VP RTC5B ECO controller,
CZ-CAPE2 for solenoid valve kit
PAW-VP•LDHW - Technical Manual – 2019-11
6
7
5
4
Ø15 mm
N
DHW