Item
TPS
Output voltage (*1)
With throttle valve fully
closed
TPS1
TPS2
Throttle valve opening angle
(*1)
With throttle valve fully
closed
Input voltage
SPS
Output voltage
F
N
R
Input voltage
Oil pressure sensor
Input voltage
Output voltage (*1)
At 392.0 kPa (3.92 kgf/cm
56.8 psi)
At 784.0 kPa (7.84 kgf/cm
113.7 psi)
(*1) The figures are for reference only.

VCT system

Item
OCV
Input voltage
Resistance
At 20 °C (68 °F)
Item
OCV
Input voltage
Resistance
At 20 °C (68 °F)
Unit
V
V
degree
V
V
V
V
V
V
2
,
V
2
,
V
Unit
F225FET
V
Unit
V
Electrical system technical data
Model
F300BET
0.37–0.63
2.5–3.5
4.5
4.75–5.25
0.2–1.5
2.412–2.588
3.5–4.8
4.75–5.25
4.75–5.25
2.5
4.5
Model
FL225FET
F250DET
12.0
6.7–7.7
Model
F300BET
12.0
6.7–7.7
FL300BET
0
1
2
3
4
5
6
7
FL250DET
8
9
FL300BET
10
A
1-12