12.3.3 Example of external wiring

AC power supply
100 to 240V
Breaker
Power ON
PL
MC
MC
Emergency
stop
MC
Power supply for load
connected to PLC output
For details on emergency stop
operation, refer to "DESIGN
PRECAUTIONS" at "Safety
Precautions" field.
*1.
The output circuit of this PLC does not have a built-in fuse.
Provide a fuse suitable to each load to prevent blowout of the wires on the circuit board caused by output
element fracture due to load short-circuiting.
*2.
" " represents vacant terminals.
WIRING PRECAUTIONS
Do not wire the vacant terminals externally.
Doing so may damage the product.
186
For the relay output wiring
of the main unit, refer to
Subsection 12.1.4.
MC
12.3 External Wiring for Triac (SSR) Output Type
COM0
Y0
COM2
Y2
COM4
Y10
*2
Output extension block
Fuse
*1
COM1
Y0
Y7
Load
*2
Input/output powered
Fuse
*1
COM1
Y0
Y3
Load
*2
12 Output Wiring Procedures
Main unit
relay output
triac output
extension unit
triac output