2. Input/output powered extension unit
Example of program
M8000
SEGL
Example of wiring
1) In the case of sink wiring
When inputs are used for sink only and outputs are the transistor sink type in the used input/output
powered extension unit
Transistor output (sink)
COM1
Y020
Y021
1
2
1
2
4
8
* Use a 7-segment display with a latch and a built-in BCD decoder.
2) In the case of source wiring
When inputs are used for both sink and source and outputs are the transistor source type in the used
extension unit
Transistor output (source)
+V0
Y020
Y021
1
2
1
2
4
8
* Use a 7-segment display with a latch and a built-in BCD decoder.
13.4 Seven Segment with Latch [SEGL Instructions (FNC74)/BCD Instructions (FNC18)]
D100
Y020
K1
Input/output powered extension unit
Y022 Y023 COM2 Y024 Y025 Y026 Y027
0
4
8
10
10
3
10
2
10
1
10
0
*
Input/output powered extension unit
Y022 Y023
+V1
Y024 Y025 Y026 Y027
4
8
10
0
3
2
1
0
10
10
10
10
*
13 Examples of Wiring for Various Uses
7-segment display to be used for sink wiring
(in the case of transistor output)
PLC
FX
-32ET
2N
FX
-48ET
2N
1
2
3
10
10
10
7-segment display to be used for source wiring
(in the case of transistor output)
PLC
FX
-32ET-ESS/UL
2N
FX
-48ET-ESS/UL
2N
10
1
10
2
10
3
7-segment display
+
Y
Signal
Internal
circuit
COM1
-
7-segment display
+V0
+
Y
Signal
Internal
circuit
-
197