Saved Data Content

The following data is saved on the memory cassette.
Item
Parameters
Program
Memory
Sequence programs User-created sequence programs
Comments
File registers
Extended file registers
*1.
This function is supported in FX
special parameters saved to any FX
*2.
This function is supported in GX Works2 Ver. 1.87R or later.
*3.
The maximum number of points for the memory capacity, comments, and file registers, can be
specified when the FX
specified when a programming tool other than the FX
Description
Memory capacity setting
-
Memory capacity (default setting: 8k steps)
2k/4k/8k/16k/32k steps
-
Comment capacity
-
File register capacity
Modem initializing settings, Battery mode settings, RUN terminal settings
RS/RS2 instructions / computer link function communication settings
Positioning settings
*1*2
Special parameters
Max. 3150 points
(0 to 63 blocks,
1 block = 50 points / 500 steps)
Max. 7000 points
(0 to 14 blocks,
1 block = 500 points / 500 steps)
ER0 to ER23999 (24000 points)
PLC Ver. 2.00 or later. Do not connect a memory cassette with
3G
PLC earlier than Ver. 2.00.
3G
programming tool is selected. The maximum number of points cannot be
3G
21.5 Saved Data Content
Comments and file registers can be
created in the memory by setting
them in the parameter memory
capacity.
is selected.
3G
21 Memory Cassette
21
Saving Method
22
A
*3
Programming tool
B
Sequence program
GX Works2
GX Developer
C
D
E