Program Example2 (When Monitoring Consecutive Timers Using Operation Keys) - Mitsubishi Electric MELSEC-F FX3G Series User Manual

Hide thumbs Also See for MELSEC-F FX3G Series:
Table of Contents

Advertisement

FX
Series Programmable Controllers
3G
User's Manual - Hardware Edition

19.14.4 Program example2 (when monitoring consecutive timers using operation keys)

In this program example, the device type to be displayed on the specified device monitor screen is set to
"timer (T)". The operation keys [+] and [-] in the display module are available to scroll device numbers T0 to
T10 during monitoring.
In this program example, system information is assigned from D50 to D54 and from M50 to M64.
M8002
Initial pulse
"+" button ON
M56
"-" button ON
M55
=
K11
=
K-1
342
Specified device
monitor screen
displayed
M55
M59
Specified device
monitor screen
displayed
M56
M59
D51
D51
MOV
K50
D8300
MOV
K50
D8301
MOV
K5
D50
RST
D51
INCP
D51
DECP
D51
MOV
K0
D51
MOV
K10
D51
END
19 Display Module (FX3G-5DM)
19.14 Specified Device Monitor Function
System information (system No.1) is
set at D50 to D54.
System information (system No.2) is
set at M50 to M64.
Sets the device type to "Timer".
Resets the device number D51.
The timer number is scrolled using
the [+] or [-] button while the
specified device monitor screen is
displayed.
The device number is specified
within the allowable range.