Mitsubishi Electric MDS-B-SPJ2 Series Specification Manual page 26

Ac spindle drive unit
Table of Contents

Advertisement

The spindle motor rotation energy W is :
n
W =
120 ×
GD
M
2
GD
L
N
n
60
n =
T
2.3.3 Combination of regenerative resistor capacity and unit
The combinations of the regenerative resistor capacity (tolerable heating value) and the unit are
shown below.
Model
No regenerative
resistor
FCUA-RB04
FCUA-RB075
FCUA-RB15
FCUA-RB22
FCUA-RB37
FCUA-RB75/2
1 unit used
FCUA-RB55
FCUA-RB75/2
Two units in series
R-UNIT1
R-UNIT2
R-UNIT3
R-UNIT4
R-UNIT5
If repeated frequency operation exceeding the regenerative resistor capacity is carried
out, and over-regeneration alarm will occur and the spindle drive unit will stop.
The over-regeneration alarm detects the cumulative value of the current that flows within
a set time to the regenerative resistor. The alarm can be released just by turning the
power ON again, but do not resume operation immediately.
If operation is resumed before the regenerative resistor cools, the regenerative resistor
could burn out and fires could occur. Always resume operation after the regenerative
resistor cools.
2. Specifications
2
2
( GD
+ GD
)
M
L
4
2
: Motor rotor inertia
: Motor shaft conversion load inertia
: Motor speed
: Acceleration/deceleration frequency (times/min.)
T : Tolerable duty cycle
Tolerable
Resistance
heating
value
value
(ohm)
60W
200
80W
100
120W
60
155W
40
185W
25
340W
30
340W
20
680W
15
700W
15
700W
15
2100W
15
2100W
10
3100W
10
2π • N
2
× [
]
60
(kg•m
(kg•m
(r/min)
(sec)
Combination with spindle drive unit
-02
-04
-075
-15
2 − 5
2
)
2
)
(MDS-B-SPJ2-**)
-22
-37
-55
-75
-110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents