(3) Drive unit capacity, motor type and regenerative resistor type selection details
Name
Abbr.
SP039 ATYP
Select the capacity of the drive unit to be used.
Setting value
SP040 MTYP
Set the motor to be used. This parameter is valid only when SP034 (SFNC2) - bit 0 is set to 0.
Setting value Motor model Max. speed (rpm) Corresponding drive unit model name
SP041 PTYP
Select a value from the following table according to the regenerative resistor being used.
Setting value
Note 1)
6. Status Display and Parameter Setting
Drive unit model
0000
0001
MDS-B-SPJ2-02
0002
MDS-B-SPJ2-04
0003
MDS-B-SPJ2-075
0004
MDS-B-SPJ2-15
0005
MDS-B-SPJ2-22
0006
MDS-B-SPJ2-37
0007
MDS-B-SPJ2-55
0008
MDS-B-SPJ2-75
0009
MDS-B-SPJ2-110/110C
1000
1001
SJ-P0.2A
1002
SJ-P0.4A
1003
SJ-P0.75A
1004
SJ-P1.5A
1005
SJ-P2.2A
1006
SJ-P3.7A
1007
SJ-PF5.5-01
1008
SJ-PF7.5-01
1009
SJ-PF11-01
Regenerative resistor
model
0000
2000
No connection
2100
FCUA-RB04
2200
FCUA-RB075
2300
FCUA-RB15
2400
FCUA-RB22
2500
FCUA-RB37
2600
FCUA-RB55
2700
FCUA-RB75/2
2800
R-UNIT1
2900
R-UNIT2
2A00
R-UNIT3
2B00
R-UNIT4
2C00
R-UNIT5
This setting for the FCUA-RB75/2 is used when only one unit is used, or when two units
connected with a parallel connection are used.
Description
10000
MDS-B-SPJ2-02
10000
MDS-B-SPJ2-04
10000
MDS-B-SPJ2-075
10000
MDS-B-SPJ2-15
8000
MDS-B-SPJ2-22
8000
MDS-B-SPJ2-37
8000
MDS-B-SPJ2-55
8000
MDS-B-SPJ2-75
6000
MDS-B-SPJ2-110/110C
Capacity [W]
Resistance value [Ω]
60
80
120
155
185
340
340/680
700
700
2100
2100
3100
6 − 15
200
100
60
40
25
20
30/15
(Note 1)
30
15
15
10
10
TYP
HEX
setting
HEX
setting
HEX
setting