11.2 DRIVE-CLiQ coupling

11.2
DRIVE-CLiQ coupling
11.2.1

Description

The DRIVE-CLiQ coupling is used to connect two DRIVE-CLiQ cables in accordance with
degree of protection IP67 acc. to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
Information on the permissible cable length can be found in Section "DRIVE-CLiQ signal
cables (Page 283)".
11.2.2

Safety instruction for DRIVE-CLiQ cables

NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when incorrect or unreleased
DRIVE-CLiQ cables are used.
• Only use suitable DRIVE-CLiQ cables that have been released by Siemens for the
270
respective application.
SINAMICS S120 Combi