Siemens SINUMERIK 840D sl Function Manual page 694

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Detailed description
2.7 Program operation mode
ASUB with REPOSA
An ASUB with REPOSA can be initiated in the AUTOMATIC status.
Example:
N10 G0 G91
N20 Y10
N30 X20
N40 REPOSA
If an ASUP is started during block search after the output of the accumulated part program
blocks, the NCK stops before executing the REPOSA block and the following interface signal
is set:
NST DB21, ... DBX318.0 = 1 (ASUP is stopped)
Note
In the situation described above, the signal: "Asup-Done" is not yet set by PLC function block
FC9.
When an ASUB is completed without REPOS, the signals
"Asub–Done" and
NST DB21, ... DBX318.0 (ASUP is stopped) together in time.
Starting ASUBs in spite of active read-in disable and/or IPO single block (SBL1)
To start ASUPs despite active read-in disable:
DB21, ... DBX6.1 == 1 (read-in disable) or IPO single block (SBL1)
the machine data must be parameterized as follows:
• MD10702 $MN_IGNORE_SINGLEBLOCK_MASK (Note prevention of single-block stop)
• MD11602 $MN_ASUP_START_MASK (Ignore stop conditions for ASUBs)
• MD20116 $MC_IGNORE_INHIBIT_ASUP (execute interrupt program in spite of read-in
• MD20117 $MC_IGNORE_SINGLEBLOCK_ASUP (Execute interrupt routine in single
136
disable)
block completely)
;
;
;
;
;
;
Basic logic functions: Mode group, channel, program operation, reset response (K1)
ASUP program
Function Manual, 11/2006, 6FC5397-0BP10-2BA0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di slSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840d powerlineSinumerik 840de powerline ... Show all

Table of Contents