Automatic ASUB start
The ASUB in the path:
/_N_CMA_DIR/_N_PROG_EVENT_SPF
is automatically started with the machine data:
MD11450 $MN_SEARCH_RUN_MODE, Bit1 = 1
in the SERUPRO approach after the following sequence:
1. The SERUPRO operation has been performed completely.
2. The user presses "Start".
3. Automatic ASUB start.
4. The NCK stops automatically before the REPOS part program command
5. The user presses "Start" again.
6. The NCK executes the REPOS movement and continues the part program at the target
Basic logic functions: Mode group, channel, program operation, reset response (K1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
and Alarm 10208 "Press NC Start to continue the program" appears.
block.
Note
The automatic ASUB start with MD11450 requires Starts to continue the program.
The procedure is in this respect similar to other search types.
Detailed description
2.6 Block search Type 5 SERUPRO
57