Detailed description
2.3 Type -specific output behavior
2.3
Type-specific output behavior
Function
The output behavior of the auxiliary function relative to a traverse motion programmed in the
part program block can be defined type-specifically in the following machine data:
• MD22200 $MC_AUXFU_M_SYNC_TYPE (output time M functions)
• MD22210 $MC_AUXFU_S_SYNC_TYPE (output time S functions)
• MD22220 $MC_AUXFU_T_SYNC_TYPE (output time T functions)
• MD22230 $MC_AUXFU_H_SYNC_TYPE (output time H functions)
• MD22240 $MC_AUXFU_F_SYNC_TYPE (output time F functions)
• MD22250 $MC_AUXFU_D_SYNC_TYPE (output time D functions)
• MD22252 $MC_AUXFU_DL_SYNC_TYPE (output time DL functions)
Output behavior
The following output behaviors can be parameterized:
MD $MC_AUXFU_xx_SYNC_TYPE = <value>
Value
0
1
2
3
4
For a description of the various output behaviors, see Section "Parameter: Output
Behaviors" of the predefined auxiliary functions.
Note
For the output behaviors that can be set for each type of auxiliary function, please refer to
the relevant detailed machine data description.
References:
/AMD/ Exhaustive Description of Machine Data
34
Meaning
Output prior to motion
Output during motion
Output at block end
No output to the PLC
Output according to the predefined output specification
Basic logic functions: Auxiliary Function Output to PLC (H2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0