Devices that are out of the range set in "Device Setting" in the CPU parameter are not included in the sampling target.
In addition, the devices out of the range are displayed in red.
For the actual target range, check the sampling target column.
Procedure for moving sampling target devices to the device individual specification
The following shows the procedure for moving sampling target devices specified for the device/label batch specification to the
device individual specification.
Operating procedure
3 RECORDING SETTING
58
3.3 Device/Label Sampling Setting
1.
Select the checkbox of "Specify Device/Label in batch"
in "Device/Label Sampling Target Setting."
2.
Open the "Device/Label Sampling Target List" screen.
Click the [Device/Label Sampling Target List] button in
"Device/Label Sampling Target Setting."
3.
Select a device displayed in "Sampling Target Device
List."
The cells in the "Device/Local Device," "Start Device," and
"End Device" columns must be selected.
4.
Press the + keys to copy them, then click the
[Close] button.
5.
Open the "Device Individual Specification" screen.
Click the [Setting] button next to "Device Individual
Specification" in "Device/Label Sampling Target
Setting."
6.
Select the last blank row in "Device Individual
Specification" and press the + keys to paste
them.
7.
Then, click the [OK] button.