Toro Groundsmaster 5900 Operator's Manual page 45

Hide thumbs Also See for Groundsmaster 5900:
Table of Contents

Advertisement

Note:
The soot load value varies as the
machine is operated and DPF regeneration
occurs.
Figure 40
Soot-Load Table
Important Soot Load Values
0% to 5%
78%
100%
122%
3.
Press button 4 to return to the technician screen
or press button 5 to exit the service menu and
return to the home screen.
Passive DPF Regeneration
Passive regeneration occurs as part of normal
engine operation.
While operating the machine, run the engine at
full-engine speed and high load when possible to
promote DPF regeneration.
Assist DPF Regeneration
The engine computer adjusts engine settings to
raise the exhaust temperature.
While operating the machine, run the engine at
full engine speed and high load when possible to
promote DPF regeneration.
g241816
Regeneration State
Minimum soot load range
The engine computer performs
an assist regeneration.
The engine computer
automatically requests a
parked regeneration.
The engine computer
automatically requests a
recovery regeneration.
Reset Regeneration
CAUTION
The exhaust temperature is hot (approximately
600°C (1,112°F) during DPF regeneration. Hot
exhaust gas can harm you or other people.
• Never operate the engine in an enclosed
area.
• Make sure that there are no flammable
materials around the exhaust system.
• Never touch a hot exhaust system
component.
• Never stand near or around the exhaust
pipe of the machine.
The high exhaust-temperature icon
in the InfoCenter
The engine computer adjusts engine settings to
raise the exhaust temperature.
Important:
The high exhaust-temperature
icon indicates that the exhaust temperature
discharged from of your machine may be
hotter than during regular operation.
While operating the machine, run the engine at
full engine speed and high load when possible to
promote DPF regeneration.
The icon displays in the InfoCenter while the reset
regeneration is processing.
Whenever possible, do not shut off the engine or
reduce engine speed while the reset regeneration
is processing.
Important:
Whenever possible, allow the
machine to complete the reset regeneration
process before shutting off the engine.