7-3. LEV
(1) Function
- It lowers the pressure of refrigerant, decreasing the temperature of the evaporator.
- It improves the efficiency of the compressor cycle.
- It adjusts the amount of refrigerant that flows into the evaporator.
(2) Operating Structure
Air coming from the
outside
※ Refrigerant Circulation Map
High pressure
Compressor
Low pressure
side
Evaporator
Evaporator
Expansion valve
Condensed, liquefied refrigerant changes into a low tempera-
Condenser
ture and low pressure state by the LEV. As the low temperature
and low pressure refrigerant passes through the evaporator, it
side
absorbs the heat of the air coming from outside and turns into
gas. Meanwhile, the temperature of outside air decreases as
the evaporator performs heat exchange. For the reference, the
temperature of the evaporator can be controlled by the LEV.
Expansion valve
Condenser
Compressor
(LEV)
53
Hot air flowing
to the outside