11-2. Cycle Characteristics - Styling
Pre
Steam
2(M1050 ~
1800)
Normal
2(M1050 ~
Light
1800)
Heavy
2(M1050 ~
1800)
Moving
hanger
-
operation
Water supply/
drain pump
Steam heater
Component
Main fan
used
Motor
Heat to 95 ℃
after supplying
water to full
level.
Operation
Water supply
error occurs
when the full
water level is
Other
not detected
within the
maximum
duration (5
minutes).
Pre
Steam
Heat
9 (M 1050)
-
4 (M 1050)
13 (M 1050)
-
-
Comp
STEAM HEATER
LEV
MAIN FAN MOTOR
Steam heater
Water drain
pump
Main fan motor
Increase internal
Operate the steam
temperature to
heater for the set
maximize the
duration to inject
steam effect.
steam.
When Duct In is
When low water
maintained for
level is detected
10 seconds at
during heating, the
a temperature
next cycle starts.
above 40 ℃, the
- LEV is at 200 when
next cycle starts
the cycle starts.
after 10 minutes.
Stay
Cooling
2 (P180/M1050)
1 (P180/M1800)
-
1 (P180/M1800)
5 (P200/M1050)
3 (P200/M1800)
Operation: 30 seconds after the cycle started
MAIN FAN MOTOR
MAIN FAN
M/H MOTOR
MOTOR
M/H MOTOR
- Styling course
Operate the main
conducts M/H
fan and M/VIH
operation to
for the set
maximize the
duration.
efficiency of
wrinkle removal.
- Sterilization
course turns
off all devices
and stands by
to maximize the
sterilization effect.
It turns off all
Main fan and
devices and
moving hanger
stands by when
operate for the
the cycle starts.
set duration.
※ P : Pulley RPM, M : Motor RPM
※ Data View Pulley RPM = Pulley RPM × 3/5
62
Drying
22
(P180/M1200~
1800)
14
(P180/M1200~
1800)
42
(P200/M1200~
1800)
Water supply/drain pump
Comp
LEV
Main fan motor
M/H motor
Operate the main fan and
comp for the set duration.
Comp operates when the