Service Flow for Symptoms

12-1 When the circuit breaker goes down
Did you connect it to the power strip?
YES
Did you use the LG styler together with a high-capacitance
home appliance (such as a heater, dryer, drum-type washing
machine, or an air conditioner)?
NO
Ask the electric company to check the wirings of the house.
The circuit breaker goes down when I operate the styler.
Are you using the power strip?
If you use the LG styler together with a high-capacitance home appliance on the same outlet or
use the power strip, the circuit breaker may go down due to
excessive load. Do not use the styler with other electronic devices.
※ Caution: Check if the power strip has the
ground terminal. Power strip without the ground terminal may cause
electric shock or explosion.
2. Did you use multiple electronic devices at the same time?
If you use the LG Styler together with a high-capacitance home appliance (such as a heater, dryer, drum-type washing
machine, or an air conditioner), the total amount of electricity in use can exceed the amount of electricity allowed for your
house, which in turn causes the breaker to go down. Check the voltameter to see the rated capacity. If it is 30 A, maximum
capacity is 6000 W. If it is 40 A, maximum capacity is 8000 W.
※ Electric capacity of LG styler is 1700 W.
3. Did you connect all devices to different outlets?
In many cases, outlets installed on the wall may be connected to the same circuit. In that case, even if you are using different
outlets, the circuit breaker may go down if excessive number of electric devices are used. In this case, call the electric
company and have your wirings inspected.
YES
Connect the power to outlet.
YES
Use the product within the allowed electric capacity.