LG Styler S3RERB Service Engineering Manual page 74

Hide thumbs Also See for Styler S3RERB:
Table of Contents

Advertisement

12-5. Water leak
1) Leakage in the Product
Is the tray properly installed?
YES
Does the leakage occur in water supply tank?
YES
Is the gasket of the door ASM properly assembled?
YES
Is the hose properly assembled?
- Connection between water supply tank and water supply pump
- Connection between water supply pump and check valve
- Connection between check valve and AG
- Connection between AG and nozzle
- Connection between nozzle and lower part of heat exchanger
- Connection between lower part of heat exchanger and inlet duct sump
- Connection between inlet duct sump and water drain pump
- Connection between water drain pump and holder
- Connection between holder and inlet duct sump
• Water leaks on the floor.
▶ Check if the styler tray is properly installed.
- Water tray is designed to prevent your feet from being caught under the product. It also prevents the condensed water from falling
onto the floor during the steam injection. If the water tray is not properly installed, condensed water may fall on the floor. (The tray can
be easily attached/detached for cleaning.)
※ When you install the tray, be sure to push the tray until it fits in completely.
Normal assembly
NO
NO
Check for the leakage of the water supply tank.
NO
Reassemble the gasket and check again.
NO
Assemble the corresponding hose properly.
Misassembly
74
Install the tray properly.

Advertisement

Table of Contents
loading

Table of Contents