11-2. Cycle Characteristics - Drying
Pre
Steam
Normal
-
-
Delicates
-
Time Dry
Moving hanger
-
operation
Water supply/
drain pump
Steam heater
Component used
Main fan
Motor
Heat to 95 ℃ after
Operation
supplying water to
full level.
Water supply
error occurs when
the full water level
Other
is not detected
within the
maximum duration
(5 minutes).
Pre
Steam
Heat
-
-
-
-
Comp
LEV
STEAM HEATER
Steam heater
Water drain pump
MAIN FAN MOTOR
Main fan motor
Increase internal
Operate the steam heater
temperature to
for the set duration to inject
maximize the steam
steam.
effect.
When Duct In is
- When low water level is
maintained for
detected during heating,
10 seconds at a
the next cycle starts.
temperature above
40 ℃, the next
- LEV is at 200 when the
cycle starts after 10
cycle starts.
minutes.
Stay
-
-
-
-
-
-
-
Operation: 30 seconds after the cycle started
MAIN FAN
MOTOR
M/H MOTOR
- Styling course
conducts M/H
operation
to maximize
the efficiency
of wrinkle
removal.
- Sterilization
course turns
off all devices
and stands by
to maximize
the sterilization
effect.
※ Data View Pulley RPM = Pulley RPM × 3/5
63
Cooling
Drying
120 (P120/
-
M1200~1800)
-
150 (P120/
-
M1600)
30~150 (P120/
M1200~1800)
Water supply/drain pump
Comp
MAIN FAN MOTOR
LEV
M/H MOTOR
Main fan motor
M/H motor
Operate the main
Operate the main fan and
fan and M/VIH
comp for the set duration.
- Comp operates 1 minute
after the cycle starts.
※ P : Pulley RPM, M : Motor RPM