Huawei Eudemon8000E Series Manual page 87

Hardware description
Table of Contents

Advertisement

HUAWEI Eudemon8000E Firewall
Hardware Description
Table 4-7 Description of the indicators on the AC power module
Indicator
RUN
ALARM
FAULT
The AC power module provides the following functions:
l
l
l
l
Table 4-8
Table 4-8 Technical parameters of the AC power supply module
Item
Type
Dimensions (width x depth x
height)
Weight
Number of power inputs
Maximum input voltage
range
Maximum input current
Output voltage
Maximum output current
Maximum output power
Issue 01 (2012-11-07)
Color
Green
Amber
Red
Protection against overcurrent of output power
Protection against overvoltage of output power
Protection against short circuit
Alarm functions
lists the technical parameters of the AC power module.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
It indicates the running status. If it is steady on, the
power module is working normally.
It indicates alarms. If it is on, a recoverable fault
occurs on the power module.
l If it is blinking, the communication is cut off.
l If it is steady on, faults occur, such as overvoltage
or undervoltage of input power or overcurrent.
It indicates a fault. If it is steady on, an unrecoverable
fault occurs on the power module. For example, fans
become faulty, no current is output, or output current
is short circuited.
Technical Parameter
EPW30B-48A
40 mm x 116 mm x 208 mm
1.8 kg
1
180 V AC to 264 V AC; 50/60 Hz
10 A
-53.3V
-53.3V/30A
1600 W
4 E8000E-X3 Chassis Overview