ABB ACS560 Quick Installation And Start-Up Manual page 40

Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

40 EN - Quick installation and start-up guide
Auto configuration of I/O's and fieldbus module
You can configure the connected optional modules or/and fieldbus modules automatically.
1. Switch off the drive and connect the required modules. For more information on optional
modules and its installation, see chapter Electrical installation in the hardware manual.
2. Switch on the drive and set parameter 07.35 Drive configuration bit list values to 0.
3. Restart the drive.
The drive configures the connected modules, its respective parameters and the fieldbus
settings.
For example, to auto configure the BIO-01 module and/or FPBA fieldbus modules, set
parameter 07.35 Drive configuration bit list values to 0 and restart the drive. The drive
EN
configures the following parameters automatically:
sets parameter 07.35 Drive configuration bits 5 (FPBA-01) and 8(BIO-01) to ON,
HI
enables BIO-01 related parameters, and
sets the profibus communication macro configuration. For information on communication
macro default parameters, see chapter Parameter default values for different
communication macros in the firmware manual.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents