Code
FA.32
FA.33
When F0.02 set to 4,FA.32 will be used to set ACC/DEC time selection for step 0~7
and FA.32 will be used to set ACC/DEC time selection for step 8~15.
Code
FA.34
0: Stop after one cycle:Inverter stops automatically as soon as it completes one
cycle,and it needs run command to start again.
1:Hold last frequency after one cycle:Inverter holds frequency and direction of last
step after one cycle.
2: Circular run: Inverter continues to run cycle by cycle until receive a stop command.
Fig.6-25 Multi-steps speed operation diagram
ACC/DEC time selection for step 0~7
ACC/DEC time selection for step 8~15
Simple PLC mode
Name
Name
117
Setting Range
0~0xFFFF0 00
0~0xFFFF0 00
Setting Range
0ÿ^20 20