Craftsman G10-0R7G-2SB Manual page 63

Table of Contents

Advertisement

2: Forbid to run in reverse direction. It can be used in some special cases if the reverse
running is disabled.
Code
F0.14
The advantage of high carrier frequency:ideal current waveform,little current harmonic
wave and motor noise.
The disadvantage of high carrier frequency:increasing the switch loss,increasing
inverter temperature and the impact to the output capacity. The inverter needs to derate
on high carrier frequency. At the same time, the leakage and electrical magnetic
interference will increase.
Applying low carrier frequency is contrary to the above,too low carrier frequency will
cause unstable running,torque decreasing and surge.
The manufacturer has set a reasonable carrier frequency when the inverter is in
factory. In general, users do not need to change the parameter.
Name
Carrier frequency
Fig.6-2 Effect of carrier frequency
63
Setting Range
1.0ÿ^16.0KHz0 Depend on
model0

Advertisement

Table of Contents
loading

Table of Contents