Code
F5.09
Setting the working logic of X terminal.
0: On valid
1: Off valid
Code
F5.10
This parameter is used to determine how fast UP/DOWN setting changes.
Code
F5.11
F5.12
F5.13
F5.14
F5.15
These parameters determine the relationship between analog input voltage and the
corresponding setting value.When the analog input voltage exceeds the range between
lower limit and upper limit,it will be regarded as the upper limit or lower limit.
The analog input All can only provide voltage input,and the range is 0Vÿ^10V.
For different applications,the corresponding value of 100.0% analog setting is
different.For details,please refer to description of each application.
The following illustration shows several set of
Note: Al1 lower limit must be less or equal to Al1 upper limit.
X terminal trait selection
Name
UP/DOWN setting change rate
Name
AI1 lower limit
AI1 lower limit corresponding setting
AI1 upper limit
AI1 upper limit corresponding setting
AI1 filter time constant
Name
conditions.
88
Setting Range
0ÿ^10 00
Setting Range
0.01ÿ^50.00Hz/S
0 0.500
Setting Range
0.00ÿ^10.00V0 0.00V0
-100.0ÿ^100.0%0 0.0%0
0.00ÿ^10.00V0 10.00V0
-100.0ÿ^100.0%
0 100.0%0
0.01ÿ^10.00S0 0.10S0