2:Invalid,the function of""' ",""( "and terminal UP/DOWN is invalid, and the setting will
be cleared automatically.
3:Valid during running. The function of""' ",""( "and terminal UP/DOWN is valid
during running and the setting will be cleared automatically when the inverter stops.
4:When the keyboard setting frequency is modified, the ""' ",""( " of the keyboard and
the terminal UP/DOWN setting are automatically cleared.
Note:When the Default is restored, the value of keypad and UP/DOWN will be cleared.
Code
F0.11
F0.12
Acceleration time is the time of accelerating from 0Hz to maximum frequency (F0.07)
Deceleration time is the time of decelerating from maximum frequency (F0.07) to 0Hz
Please refer to following figure.
Name
Acceleration time 1
Deceleration time 1
61
Setting Range
0.1ÿ^3600.0S
0 Depend on model0
0.1ÿ^3600.0S
0 Depend on model0