When you strip a power cable, do not damage the conductor of the cable.
If the bare crimping terminal is not provided by Huawei, you can adjust the value of L as
required.
Figure 5-7 Stripping a power cable (JG terminal)
Table 5-2 Mapping between the cross-sectional area of the conductor and the value of L
Cross-Sectional Area of Conductor
(mm
16 (0.025)
25 (0.039)
35 (0.054)
50 (0.077)
Step 2 Put the heat shrink tubing onto the bare crimping terminal, as shown in Figure 5-8.
Figure 5-8 Putting the heat shrink tubing onto the bare crimping terminal
Issue 01 (2016-04-15)
(in.
))
2
2
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Value of L (mm(in.))
13 (0.51)
14 (0.55)
16 (0.63)
16 (0.63)