4 Installation

Install the ANUJ5010 Aicure under the conditions below.

4.1 Installation Conditions

Warning

4.2 General Guide for Irradiation Distance and UV Intensity

At light modulation of 100%, room temperature of 25
1) Ambient temp.: Main unit: 10 to 40
o
Head: 5
C to 35
2) Relative humidity: No greater than 85%, with no condensation
3) Make sure the rubber legs are set horizontally parallel.
4) In order to avoid damage due to overheating, do not use if the area
around the system is blocked.
5) The dimensions of the main unit are 85 x 218 x 230 mm (LxHxD),
but you should take into account the state of the unit with an LED
head attached.
The minimum allowable bending radius for the LED head cord is
33 mm. Using the cord with a curve radius of less than 33 mm
could damage it.
Do not place items on top of the main unit, or block its air vents.
Excessive heat could damage the unit due to overheating.
Mount the LED head on the jig so that the irradiation distance is in
accordance with the size of the area to be irradiated (irradiation
diameter) and the required UV intensity. Below is a general guide for
irradiation distance (WD) and UV intensity.
Note: See page 13 for the dimensions of the cooling device.