Parameter description
6.3 Vector Control Parameters
Code
Description
Torque control
F3.12
speed limit
Torque control
F3.13
speed limit
digital setting
Encoder pulse
F3.14
number
Motor and PG
F3.15
reduction ratio
F3.16
PG direction
ACC/DEC limit
F3.17
controlled by
SVC speed
F3.18
calculation
filter
F3.19
SVC mode
SVC mode2
F3.20
flux weaken
coefficient
Flux weaken
F3.21
control
selection
Torque limit
compensation
F3.22
coefficient
while constant
power output
F3.23
Reserved
Torque ref.
F3.24
terminal single
modulation
SINAMICS V50 converter
37
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Setting range
0: digital setting
(F3.13)
1: AI1
2: AI2
3: PULSE
4: Comm.
0.00~550.0Hz
1~9999
0.010~50.000
0: Forward
1: Reverse
0: Limited
1: No limited
PG
0~15
0: Mode1
1: Mode2
20~500%
0: Disable
1: Enable
30.0~300.0%
Reserved
0.0~10%
Default
Modify
0
о
50.00Hz
о
1000
о
1.000
о
0
о
0
о
5
о
0
о
100%
о
0
о
200%
о
Reserved
Reserved
0.00%
о
Modbus
Address
040CH
040DH
040EH
040FH
0410H
0411H
0412H
0413H
0414H
0415H
0413H
0418H