Parameter description
6.7 Output terminal
Code
Description
Preset Counting
F7.13
arrival value
Preset Timing
F7.14
arrival value
AI1 compare
F7.16
threshold 1
AI1 compare
F7.17
threshold 2
Analog compare
F7.18
hysteresis error
AO1 output
F7.19
selection
AO2 output
F7.20
selection
DO output
F7.21
selection
SINAMICS V50 converter
50
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Setting range
0~9999
0.0 ~ 6553.0s
0.00~10.00V
0.00~10.00V
0.00~30.00V
0: NULL
1: Running freq.
(0~max
frequency)
2: Setting freq.
(0~max
frequency)
3: Output current
(0~2 times of
drive rated
current)
4: Output voltage
(0 ~ Max
Voltage)
5: PID setup (0~
10V)
6: PID feedback
(0~ 10 V)
7: Calibrating
signal (5V)
8: Output torque
(0 ~ 2 times of
motor rated
torque)
9: Output power
(0 ~ 2 times of
drive rated
power)
10: Bus voltage
(0~1000V)
Default
Modify
0
о
0.0s
о
0.00V
о
0.00v
о
0.20V
о
1
о
0
о
0
о
Modbus
Address
080DH
080EH
0810H
0811H
0812H
0813H
0814H
0815H