Mitsubishi Electric AJ65VBTCU-68DAVN User Manual page 45

Programmable controller digital-analog converter module
Hide thumbs Also See for AJ65VBTCU-68DAVN:
Table of Contents

Advertisement

4 SETUP AND PREPARATION BEFORE OPERATION
Name and
Number
appearance
Operation status
1)
display LED
Offset/gain
2)
adjusting LEDs
SELECT/SET
3)
switch
UP/DOWN
4)
switch
Mode select
switch
5)
(Factory-set to
"0")
Transmission
speed setting
switches
6)
4 - 4
ON : Power supply on
POWER
OFF : Power supply off
On
Flashing : 0.1s intervals : Output range setting error, mode select switch setting error.
Normal
mode
RUN
Off
On
Flashing : 0.1s intervals : Mode select switch setting error.
Test
mode
Off
On : Normal communication
L RUN
Off : Communication cutoff (time expiration error)
On : Indicates that transmission speed setting or station number setting is outside the range.
Flicker at fixed intervals
L ERR.
Flicker at unfixed intervals : Indicates that you forgot fitting the terminating resistor or the module
Off : Indicates normal communications.
TEST
Normal mode
CH
OFFSET
Test mode
GAIN
Used to make offset/gain setting in the test mode.
Used to adjust the offset value and gain value of the channel specified by the SELECT/SET switch.
The switch to be used for selecting the mode among Ver.
station)/Normal mode/Test mode
Ver.1 remote device station
(Ver.1-compatible slave station)
Ver.2 remote device station
(Ver.2-compatible slave station)
-
Set Value
4
0
OFF
1
OFF
2
OFF
3
OFF
4
ON
Always set the transmission speed within the above range.
The switches are all factory-set to OFF.
Making any other setting than the above will result in an error flickering the "L ERR." LED.
Confirm the transmission speed setting switch numbers on the seal located on the side face of the
connector for analog I/O.
Description
: Normal operation
This module is used as the Ver.2 remote device station (Ver.2
compatible slave station) when the network parameter mode
is set to remote network Ver.1 mode.
0.5s intervals : Average value setting (count) time error. Mode select switch
setting is changed after power-on.
: 24VDC power supply shutoff or watchdog timer error occurred.
: Indicate that the SELECT/SET switch is in the SET position.
0.5s intervals : An attempt was made to make setting outside the setting
range at the time of offset/gain setting.
: Indicates that the SELECT/SET switch is in the SELECT or center position.
: Indicates that transmission speed setting or station number setting
was changed from that at power-on.
or CC-Link dedicated cable is affected by noise.
Normally OFF.
TEST : ON
The OFFSET/GAIN/ CH
SELECT/SET switch is moved to SELECT. (Refer to section 4.5)
AJ65VBTCU-68DAVN
0: Normal mode
1: Test mode (User range setting 1)
2: Test mode (User range setting 2)
3: Normal mode
4: Test mode (User range setting 1)
5: Test mode (User range setting 2)
6 to 7: Use prohibited
Setting Switches
2
OFF
OFF
ON
ON
OFF
LEDs lit change every time the
remote device station (Ver.
Transmission Speed
1
OFF
ON
OFF
ON
OFF
MELSEC-A
-compatible slave
156kbps
625kbps
2.5Mbps
5.0Mbps
10Mbps
4 - 4