Configuring the instructions
4.5 Programming instructions
4.5.1.3
Param_RFID181EIP
The "Param_RFID181EIP" instruction can be used to transfer the configuration data to
an RFID181 EIP communication module.
Figure 4-4
Table 4- 13 Explanation for the instruction "Param_RFID181EIP"
Parameter
MOBY_MODE
BAUD_RATE
READER_
CONFIGDATA
MSG_PARAM
32
Instruction "Param_RFID181EIP"
Data type
SINT
SINT
IID_DATA_
RFID181EIP
MESSAGE
Default values
Description
0
MOBY mode for the connected Ident
system on the channels of the RFID
181EIP:
•
0x05 = RF200/RF300;
MV400/MV500
0
Transmission speed for serial com-
munication on the RFID 181EIP:
•
0x01 = 19.2 kBd
•
0x02 = 38.4 kBd
•
0x03 = 57.6 kBd
•
0x04 = 115.2 kBd
--
The configuration variable contains
the buffer for the configuration data
and the "HW_CONNECT" variables
which are required for operation of
the individual channels.
You can find detailed information on
creating variables in the section
"Creating configuration variables
(Page 17)".
--
The message variable transfers the
configuration data from the buffer of
the configuration variable to the
Ident device.
You can find detailed information on
the creation and configuration of
variables in the section "Configuring
the message variable for configura-
tion (Page 18)".
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04