Reset_Rf300 - Siemens SIMATIC Ident Function Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Configuring the instructions
4.5 Programming instructions
4.5.5.4

Reset_RF300

Figure 4-25 Instruction "Reset_RF300"
Table 4- 45 Explanation for the instruction "preset_RF300"
Parameter
TAG_CONTROL
TAG_TYPE
RF_POWER
62
Data type
Default values
SINT
1
SINT
0
SINT
0
Description
Presence check
0 = Off
1 = on
4 = presence (antenna is off. The
antenna is turned on only when a
Read or Write command is sent.)
Transponder type:
1 = every ISO transponder
0 = RF300 transponder
Output power; only relevant for
RF380R
RF power from 0.5 W to 2 W in in-
crements of 0.25 W (range of values:
Default value: 0x00 ≙ 1.25 W.
0x02 ... 0x08).
This setting is not necessary with
the RF380R readers of the 2nd gen-
eration (6GT2801-3BAx0) because
the power limits are optimized au-
tomatically depending on the reader-
transponder distance.
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04