Q.8.1
What will happen if a VPI/VCI value cell not enabled by the receive lookup table has been received, and is it
reported?
A.8.1
If a VPI/VCI value cell not enabled to be received is received, that cell is internally discarded. At this time, no
notification, such as an interrupt, is made.
Reference: µ PD98409 User's Manual 5.5.4 Setting of receive look-up table
Q.8.2

How is a CRC-10 error reported when a Raw cell is received? Is it possible to disable error checking?

A.8.2
A CRC-10 error is reported by the CE bit in the Raw cell data when a Raw cell is received. At this time, no
indication, such as an interrupt, is made. The CRC-10 error check is always enabled. When the CRC-10 error
check is not used, ignore the CE bit in the Raw cell data.