HP E1343A User Manual page 80

Relay multiplexer
Table of Contents

Advertisement

Throughput Speed
Table B-1. Computer Configurations used with Relay Multiplexers
Computer
E1300/E1301 IBASIC
(Absolute Addressing)
(Select Code 8)
External Computer
(over HP-IB to E1300/E1301
Mainframe
or E1405/E1406 Command
Module)
V/382 Embedded Computer
(C-Size system)
LADDR : logical address.
(LADDR * 64)
: multiply quantity, then convert to a hexadecimal number (e.g. 80 * 64)
16
When using DIAG:PEEK? and DIAG:POKE, the width (number of bits) is 8 or 16.
Appendix B
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Throughput speed is based on the amount of command parsing and whether
the registers are accessed from the VXI backplane or from the HP-IB. The
computer configurations which allow faster throughput relative to each
other are summarized below.
1. HP E1499A V/382 Controller with
(register access is from VXI backplane).
2. E1300/01 IBASIC absolute addressing with
(register access is from VXI backplane).
3. E1300/01 IBASIC select code 8 with
access is from VXI backplane).
4. External Computer using
(register access is over HP-IB).
5. External Computer using
(register access is over HP-IB).
Programming Method
READIO (-9826,Base_addr + offset)
WRITEIO -9826,Base_addr + offset;data
(positive select code = byte read or write
negative select code = word read or write)
READIO (8,Base_addr + reg number)
WRITEIO 8,Base_addr + reg number;data
VXI:READ? logical_address,offset
VXI:WRITE logical_address,offset,data
DIAG:PEEK? Base_addr + offset,width
DIAG:POKE Base_addr + offset,width,data
READIO (-16,Base_addr + offset)
WRITEIO -16,Base_addr + offset;data
(positive select code = byte read or write
negative select code = word read or write)
READIO
and
READIO
and
READIO
and
DIAG:PEEK?
DIAG:POKE
VXI:READ?
and
VXI:WRITE
Base Address
Base_addr = 1FC000
or
= 2,080,768 + (LADDR * 64)
offset = register offset
Base_addr = LADDR * 256
reg number = offset
logical address setting (LADDR)
offset = register offset
Base_addr = 1FC000
or
= 2,080,768 + (LADDR * 64)
offset = register offset
Base_addr = C000
16
or
= 49,152 + (LADDR * 64)
offset = register offset
= 1400
16
16
16-Channel Relay Multiplexer Registers
WRITEIO
and
WRITEIO
(register
WRITEIO
+ (LADDR * 64)
16
16
(Figure
B-1)
(Figure
B-1)/2
(Figure
B-1)
+ (LADDR * 64)
16
16
(Figure
B-1)
+ (LADDR *64)
16
(Figure
B-2)
.
79

Advertisement

Table of Contents
loading