Command Quick Reference - HP E1343A User Manual

Relay multiplexer
Table of Contents

Advertisement

Command Quick Reference

Command
ABORt
ARM
:COUNt <
number
:COUNt? [MIN | MAX]
DISPlay
:MONitor:CARD <
:MONitor[:STATe] <
mode
INITiate
:CONTinuous <
:CONTinuous?
[:IMMediate]
mode
OUTPut
[:STATe] <
>
[:STATe]?
channel _list
[ROUTe:] CLOSe <
channel _list
CLOSe? <
OPEN <
channel _list
OPEN? <
channel _list
SCAN <
channel _list
SCAN:MODE NONE|VOLT|RES|FRES
SCAN:MODE?
SCAN:PORT NONE|ABUS
STATus
:OPERation:ENABle
:OPERation[:EVENt]?
SYSTem :CDEScription? <
number
:CPON <
number
:CTYPe? <
:ERRor?
TRIGger [:IMMediate]
:SOURce BUS
:SOURce EXTernal
:SOURce HOLD
:SOURce IMMediate
:SOURce?
Command
Title
*RST
Reset
*TRG
Bus Trigger
*TST?
Self Test
72 Relay Multiplexer Command Reference
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
The following tables summarize SCPI and IEEE 488.2 Common (*) Commands for
the multiplexer modules used in a switchbox.
SCPI Commands Quick Reference
> MIN|MAX
number
>|AUTO
mode
>
>
>
>
>
>
>
number
>
>|ALL
>
IIEEE 488.2 Common Commands Quick Reference
Opens all channels, invalidates current channel list for scanning.
Sets ARM:COUN 1, TRIG:SOUR IMM, and INIT:CONT OFF.
When scan is enabled and trigger source is TRIG:SOUR BUS, use the *TRG
command to trigger the switchbox to advance the scan.
Always returns 0.
Description
Abort a scan in progress.
Multiple scans per INIT command.
Query number of scans.
Selects module to be monitored.
Selects monitor mode.
Enables/disables continuous scanning.
Query mode.
Starts a scanning cycle.
Enables/disables "Trig Out" pulse.
Query state of trig out pulse.
Close channel(s).
Query channel(s) closed.
Open channel(s).
Query channel(s) opened.
Define channels for scanning.
Selects appropriate Channel Switches for Measurements.
Query state of scan mode.
Enables Tree Switches closure as part of a Measurement.
Enables the Operation Status Register to set a bit in the
Status Register.
Returns status of Operation Status Register.
Returns description of module in a switchbox.
Sets specified module to its power-on state.
Returns the module type.
Returns error number/message in a switchbox Error Queue.
Causes a trigger to occur.
Trigger source is *TRG.
Trigger source is "Event In" BNC.
Hold off triggering.
Continuous (internal) triggers.
Query scan trigger source.
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

E1344aE1345aE1347a