Command
ABORt
number
ARM
:COUNt <
:COUNt? [MIN | MAX]
DISPlay
:MONitor:CARD <
:MONitor[:STATe] <
INITiate
:CONTinuous <
:CONTinuous?
[:IMMediate]
state
OUTPut
[:STATe] <
[:STATe]?
[ROUTe:] CLOSe <
channel _list
channel _list
CLOSe? <
OPEN <
channel _list
OPEN? <
channel _list
channel _list
SCAN <
SCAN:MODE NONE | VOLT | RES | FRES
SCAN:MODE?
SCAN:PORT NONE | ABUS
SCAN:PORT?
SETTling[:TIME] <
SETTling[:TIME]? [MIN | MAX] <
STATus
:OPERation:ENABle
:OPERation[:EVENt]?
SYSTem :CDEScription? <
:CPON <
number
number
:CTYPe? <
:ERRor?
TRIGger
[:IMMediate]
:SOURce BUS
:SOURce DBUS
:SOURce EXTernal
:SOURce HOLD
:SOURce IMMediate
:SOURce?
Command
*RST
Reset
*TRG
Bus Trigger
*TST?
Self-Test
Chapter 5
The following tables summarize SCPI and IEEE 488.2 Common (*)
Commands for the 16-Channel FET Multiplexer Modules.
SCPI Commands Quick Reference
> MIN | MAX
number
> | AUTO
mode
>
mode
>
>
>
>
>
>
>
channel_list
>
channel_list
number
>
> | ALL
>
IEEE 488.2 Common Commands Quick Reference
Title
Opens all channels and invalidates current channel list for scanning.
Sets ARM:COUN 1, TRIG:SOUR IMM, and INIT:CONT OFF.
When scan is enabled and trigger source is TRIG:SOUR BUS, use the *TRG
command to trigger the switchbox to advance the scan.
Power on interrupt returns +110.
Incorrect MFR ID or model code returns +103.
Test pass returns 0.
HP E1351A/53A 16-Channel FET Multiplexer Command Reference
Abort a scan in progress.
Multiple scans per INIT command.
Query number of scans.
Selects module to be monitored.
Selects monitor mode.
Enables/disables continuous scanning.
Query mode.
Starts a scanning cycle.
Enables/disables "Trig Out" pulse.
Query state of trig out pulse.
Close channel(s).
Query channel(s) closed.
Open channel(s).
Query channel(s) opened.
Define channels for scanning.
Selects appropriate tree Isolation switches for measurements.
Query state of scan mode.
Enables tree isolation switches closure as part of a
measurement.
Query analog bus state.
Sets delay between trigger pulse and channel closed pulse.
>
Returns current parameter in SETTling[:TIME].
Enables the Operation Status Register to set a bit in the
Status Register.
Returns status of Operation Status Register.
Returns description of module in a switchbox.
Sets specified module to its power-on state.
Returns the module type.
Returns error number/message in a switchbox error queue.
Causes a trigger to occur.
Trigger source is *TRG.
Trigger source is Digital Bus.
Trigger source is "Event In" port.
Hold off triggering.
Continuous (internal) triggers.
Query scan trigger source.
Description
Description