Application planning
4.3 Preparing the mounting surface
Drill holes for fixing points on the floor
To fasten the SICHARGE UC Dispenser, the following drill holes must be available for the
fixing points:
Figure 4-7  Fixing points of the mounting plate
Fixing to the floor
The mounting material is not included in the scope of delivery.
We recommend the following fixing material for mounting the SICHARGE UC Dispenser to the
base area:
• 6 bolt anchors M12
For example, FISCHER FAZ ΙΙ 12/20 H A4 cap nut
• 6 washers M12
• 6 nuts M12
• Sealing material to prevent the ingress of moisture, animals and insects
40