NOTICE
Accident risks
Avoid accidents and injuries as well as damages to vehicles and the SICHARGE UC Dispenser.
These are, for example, inattentiveness, slipping and tripping risks as well as vandalism.
Provide additional protective measures, for example:
• Warning signs
• Safe location of the SICHARGE UC Dispenser
• Barriers
• Training of drivers and operators
• Sufficient lighting
NOTICE
Safety area for mounting
Create a safety area around the mounting surface with warning signs and barriers.
NOTICE
Use the PPE
Use the personal protective equipment required for the work. For example:
• Protective shoes
• Helmet
• Safety vest
• Gloves
• Protective goggles
NOTICE
Risk of crushing/cutting
When mounting, look out for moving parts and protruding cables and bolts.
NOTE
Routing of DC cables to prevent radio interference
The DC charging cables from the SICHARGE UC charging station to the
SICHARGE UC Dispenser must either be buried underground or fastened directly to the floor.
We recommend using shielded cables for running the cables above ground to reduce the
electromagnetic radiation of the cables. Additional measures may be necessary, however, in
case of interferences of the radio spectrum; these include, for example, the use of EMC filters
or ferrites that must then be installed at the output of the DC charging cable.
SICHARGE UC Dispenser
Operating Instructions, 06/2023, A5E50235695-AE
Installation
5.1 Safety instructions