Switching The Scan Speed; Program Slow Scan; Turning On/Off Program Slow Scan; Configuring The Frequency Points For Program Slow Scan - Kenwood TS-890S Instruction Manual

Hide thumbs Also See for TS-890S:
Table of Contents

Advertisement

10 SCAN
Examples on the configuration of Program Scan and
VFO Scan:
• Configure the memory channels for specific band
segments such that the checkboxes for P1, P3 and
P5 are selected. Next, press F5 [SCAN]. Program
Scan starts and scanning is performed in the
frequency range registered for the respective
channels.
• Configure the memory channels for specific band
segments such that all the checkboxes are
deselected and press F [SCAN]. Or press [VFO/
PRG] to switch the display to "VFO SCAN". VFO Scan
is performed on the entire RX frequency band.
• The checkbox will remain deselected for memory
channels that do not contain any operating data.
These checkboxes cannot be selected.
• For more details on registering memory channels for
specific band segments, please refer to
the Program Scan Frequency

Switching the Scan Speed

The time interval for switching the Program Scan (VFO Scan)
frequency can be configured in modes other than FM.
1 Press F3 [–] or F4 [+] while Program Scan (or VFO
Scan) is in progress.
The scan speed is shown below the frequency display.
.
The frequency switching interval changes as follows.
Scan Speed Display
SCAN-SPD1
SCAN-SPD2
SCAN-SPD3
SCAN-SPD4
SCAN-SPD5
SCAN-SPD6
SCAN-SPD7
SCAN-SPD8
SCAN-SPD9
10-2
"Configuring
Range" on page 9-4.
Frequency Switching Interval
10 ms
30 ms
100 ms
150 ms
200 ms
250 ms
300 ms
350 ms
400 ms

Program Slow Scan

Program Slow Scan is a function that extends the frequency
switching interval (performs scan more slowly) using the
preconfigured frequency for performing Program Scan (frequency
point) and the frequencies before and after this point (segment).
Switching slowly between the specified frequency (frequency
point) and the corresponding segment allows the communication
status to be checked in detail.
• To perform Program Slow Scan, register a frequency range to
a memory channel for specific band segments in advance.

Turning ON/OFF Program Slow Scan

To combine the use of Program Slow Scan while Program Scan is
running, set Program Slow Scan to ON in advance.
• When scanned frequency falls in the segment for Program Slow
Scan during Program Scan, "SCAN-SLOW" is displayed on the
screen and the speed of frequency switching slows down.
Configure in Menu [4-02] "Program Slow Scan"
Setting Value
Off/ On (default)
Configuring the Frequency Points for Program Slow
Scan
The frequency points for extending the frequency switching
interval during Program Slow Scan can be configured as follows.
• Up to 5 frequency points can be configured for each memory
channel assigned to specific band segments (P0 to P9).
• To configure the frequency points, register a band segment to
a memory channel for specific band segments in advance.
1 Press [M/V] to switch to the memory channel mode.
2 Press F7 [M.LIST] to display the Memory Channel
List screen.
.
3 Press F2 [
] or F3 [
control to select a memory channel for specific
band segments.
4 Press F5 [SLW.SCN] to display the Program Slow
Scan screen.
.
], or turn the [MULTI/CH]

Advertisement

Table of Contents
loading