Configuring The Segment For Program Slow Scan; Scan Hold; Memory Scan; Performing Memory Scan - Kenwood TS-890S Instruction Manual

Hide thumbs Also See for TS-890S:
Table of Contents

Advertisement

5 Turn the Tuning control and align the "Current"
frequency as the frequency point for Program Slow
Scan.
6 Press any of the function keys (F2 [POINT 1] to F6
[POINT 5]) to configure the center point of the
preferred frequency range to perform Program
Slow Scan.
• Pressing and holding the key clears the frequency point that
is stored.
• Pressing and holding F7 [(CLR ALL)] clears all the
frequency points.
7 Press F1 [
] to exit the Program Slow Scan
screen.
The display returns to the Memory Channel List screen.
8 Press [ESC] to exit the Memory Channel List screen.
Pressing a function key (F2 [Point 1] to F6 [POINT 5])
that already contains a frequency point overwrites the
frequency point with the new input.
When configuring a frequency point, frequencies that are
smaller than 10 Hz are rounded off.

Configuring the Segment for Program Slow Scan

The frequency switching interval during Program Scan slows down
in the preconfigured segment that contains frequencies before and
after the frequency point for Program Slow Scan.
Configure in Menu [4-03] "Program Slow Scan
Range"
Setting Value
100/ 200/ 300 (default)/ 400/ 500 [Hz]
• For example, when 500 [Hz] is selected, the frequency
switching interval is extended to a range of ± 500 Hz from
the frequency point.

Scan Hold

While Program Scan (VFO Scan) is performed in a mode other
than FM, changing the frequency by turning the Tuning or [MULTI/
CH] control pauses the scan operation for 5 seconds.
Signals can be received temporarily without stopping the scan
operation.
Configure in Menu [4-04] "Scan Hold"
Setting Value
Off (default)/ On
When Scan Hold is set to "On", signals are received with
Program Scan paused for 5 seconds.

Memory Scan

Memory Scan allows the registered memory channel to be
automatically switched at a specific time interval for scanning.
There are 2 types of Memory Scan modes. All-channel Scan
performs scan on all the memory channels that are registered with
operating data, while Group Scan performs scan on a selected
group among the memory channels.

Performing Memory Scan

1 Press [M/V] to switch to the memory channel mode.
2 Press F5 [SCAN] to start memory scan.
• Turning the [MULTI/CH] control allows the scan channel to
jump rapidly to the next or previous channels.
• Pressing F5 [SCAN] again or pressing [ESC] ends Memory
Scan.
• The scan direction is fixed at the ascending order.
The frequency switching interval during Memory Scan is
400 ms. However, when a CTCSS tone is received in the
FM mode, the frequency switching interval is extended
to 600 ms. During Memory Scan, "SCANNING" is
displayed instead of the scan speed.

Configuring All-channel Scan and Group Scan

1 Press [M/V] to switch to the memory channel mode.
2 Press and hold F5 [SCAN] to display the Memory
Scan group screen.
.
3 Press F2 [
] or F3 [
group.
4 Press F4 [
] or turn the [MULTI/CH] control to
select whether to start scanning of the memory
channels belonging to a memory group.
• Pressing F4 [
deselects (does not perform scan) the checkbox.
• When performing All-channel Scan, select the checkboxes
for all the memory groups.
• Pressing F6 [SEL.ALL] selects the checkboxes for all
memory groups.
• Pressing F7 [CLR.ALL] deselects the checkboxes for all
memory groups.
• Memory channels are classified into memory groups as
follows. The classification of the memory groups and
channels cannot be altered.
Memory
Group
Channel
0
00 to 09
1
10 to 19
2
20 to 29
3
30 to 39
4
40 to 49
5
50 to 59
5 Press [ESC] to end the process.
SCAN 10
] to select a memory
] each time selects (performs scan) or
Memory
Group
Channel
6
60 to 69
7
70 to 79
8
80 to 99
9
90 to 99
P
P0 to P9
E
E0 to E9
10-3

Advertisement

Table of Contents
loading

Table of Contents