Configuring the NR1 Effect Level

1 Press [NR] to select Noise Reduction 1.
2 Press and hold [NR] to display the Noise Reduction
1 effect level configuration screen.
.
3 Press F4 [–]/ F5 [+] or turn the [MULTI/CH] control
to change the level of effect.
Setting Value
1 to 5 (default) to 10 (1 step)
• For NR1, configuring to a larger value reduces the noise
further. However, as the impact on the RX audio also gets
stronger if the effect level is excessively high, adjust it to an
appropriate level.
4 Press and hold [NR] or press [ESC] to end the
process.

Configuring the NR2 Correlation Time

1 Press [NR] to select Noise Reduction 2.
2 Press and hold [NR] to display the NR2 Time
Constant configuration screen.
.
3 Press F4 [–]/ F5 [+] or turn the [MULTI/CH] control
to change the correlation time.
Setting Value
2 to 20 (default) [ms] (2-step)
• As the optimal correlation time varies with the RX signal and
noise type when NR2 is used, configure the correlation time
while receiving the signals.
4 Press and hold [NR] or press [ESC] to end the
process.
NR2 adjusts the correlation time for periodic signal
extraction. It is different from NR1, which adjusts the
effect level.
REJECTING INTERFERENCE 6

Beat Canceler

Beat canceler is capable of suppressing multiple periodic
interfering signals (beats) within the RX bandwidth through digital
processing at the AF level.
This function can be used in the SSB, AM and FM modes.

Turning ON/OFF Beat Canceler

Press [BC].
Pressing [BC] each time switches the beat canceler mode in
the following sequence: "Beat Canceler 1" → "Beat Canceler 2"
→ "OFF".
• When beat canceler 1 or beat canceler 2 is ON, <<
or <<
>> is displayed on the screen.
BC
2
• Beat canceler 1 suppresses weak beats and continuous
beats. Beat canceler 2 suppresses intermittent beats such
as CW signals.
.
Although the beat canceler suppresses the overall
auditory beat, the gain of the target signal cannot be
recovered using the AGC function. Thus, if the beat
signal is larger than the target signal, using a notch filter
activates the AGC function to enhance the clarity of the
target signal.

DSP Monitor

DSP monitor is a function for temporarily expanding the passband
width of the IF filter and AF filter via DSP in order to monitor the
signal condition of nearby frequencies such as when receiving a
specific frequency using a filter with a narrow passband width
during contesting.

Assigning DSP Monitor to PF Key

Register "DSP MONITOR" in Menu [0-15] "PF A: Key
Assignment" to Menu [0-31] "Microphone UP: Key
Assignment"

Expanding the Passband Width Using DSP Monitor

Press and hold down the PF key that is assigned
with the DSP monitor function.
The passband width of the filter is expanded while the key is
held down.
During DSP monitoring, the audio peak filter is forcibly
turned OFF.
>>
BC