Hitachi PC-ARFG-E Installation & Operation Manual page 61

Wired remote controller
Hide thumbs Also See for PC-ARFG-E:
Table of Contents

Advertisement

SERVICE & INSTALLATION MENU
Element
Optional function
S4
Not used
S5
Not used
S6
Not used
S7
Not used
S8
Not used
?
N O T E
O: allows for individual setting.
X: the setting is made for all outdoor units.
–: not used.
W hen J1 is set as activated function, the room temperature indication is the sensor value set at "C8".
(1)
T he Remote Control Switch shall be installed in a proper place for the correct detection of room temperature by its temperature sensor.
(2)
T he Remote Sensor shall be installed in a proper place for the correct detection of room temperature.
(3)
I n case that automatic louver is set, the louver will keep operating in both thermo-ON and thermo-OFF condition.
(4)
0 0 standard (7-step operation); 01 draft prevention (cannot be set to the lower two steps); 02 High ceilings (cannot be set the upper two steps).
(5)
I n case that the set temperature is changed and kept within the set time at "F4", the temperature is automatically changed to "F5" and "F6". In
(6)
case that the set temperature is out of range at "F5" and "F6", it is applied within upper and lower limit for the set temperature.
W hen the unit is restarted by the remote control switch, the temperature automatically changes to the setting temperature of "F5" or "F6".
(7)
?
N O T E
On modifying the "
CF
" (air outlet louver angle change) setting, restore the power supply or allow the automatic louver to make a full cycle in
automatic mode to apply the optional setting.
The changes to the optional function settings must be done after 3 minutes have passed after startup.
It is recommended to keep track of the changes made to optional function settings, for further reference.
The optional settings are different according to the indoor and outdoor unit models. Check to ensure that the unit has the optional setting or not.
The optional functions with "X" mark at the individual setting column can change the condition only when "All Rooms" is set.
The following optional functions are disable when RPI Unit with Econofresh are installed: b7, bA, bd, bE, C1, C2, C3, C9, CA, Cd, CF, d6, E3,
E5, E7, E9, EA, FE, FF, H1, H3, H4, J2, J4, J7, J8, J9, JA, JB, K1, K2, K3, K4, K5.
56
PMML0565 rev.0 - 09/2021
Individual
Settings
setting
00
-
-
01
00
-
-
01
00
-
01
-
02
00
01
02
03
-
-
04
05
06
07
00
01
02
03
04
05
06
07
-
-
08
09
10
11
12
13
14
15
Setting conditions
Description
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions