Panasonic DVCPRO AJ-D455P Service Manual page 156

Digital video cassette recorder/ component serial interface board/ digital video interface board/ cassette adapter
Hide thumbs Also See for DVCPRO AJ-D455P:
Table of Contents

Advertisement

B00: RF ADJUST
RF ADJUST has a subscreen composition, and there is a hierarchical structure for each format.
RF ADJUST subscreen
Item
SUPER
No.
C00 PRO ADJUST
D00 DV ADJUST
C: RRO ADJUST subscreen
Item
SUPER
No.
C-1
REC ADJUST
C-2
RP ADJUST
C-3
PB ADJUST
C-4
DEFAULT
D: DV ADJUST subscreen
Item
SUPER
No.
D-1
REC ADJUST
D-2
RP ADJUST
D-4
DEFAULT
DISP.
Adjustment for DVCPRO (25 Mbps)
Adjustment for DV
• Insert a DV cassette for adjustment.
DISP.
Adjustment of the recording system for DVCPRO (25 Mbps)
Adjustment of the playback system (RP head) for DVCPRO (25 Mbps)
Adjustment of the playback system (PB head) for DVCPRO (25 Mbps)
LOAD/SAVE of the factory default adjustment values/initial values LOAD operation
• Perform operation in regard to the adjustment values for DVCPRO (25 Mbps).
• Operation is effective only after completion of loading.
Operation:
1. Move the cursor to C-4: DEFAULT.
2. Press the "
operation item.
SAVE ... Save the present set values as the factory default values.
LOAD ... Load the saved factory default values as the present set
INIT LOAD ... Load the initial values as the present set values.
3. When the SET button is pressed, the selected operation will be performed and it will
return to the item setting screen.
When the MENU button is pressed, no operation will be performed and it will return
the item setting screen.
DISP.
Adjustment of the recording system for DVCPRO
Adjustment of the playback system (RP head) for DVCPRO
LOAD/SAVE of the factory default adjustment values/initial values LOAD operation
• Perform operation in regard to the adjustment values for DVCPRO.
• Operation is effective only after completion of loading.
Operation:
1. Move the cursor to C-4: DEFAULT.
2. Press the "
operation item.
SAVE ... Save the present set values as the factory default values.
LOAD ... Load the saved factory default values as the present set
INIT LOAD ... Load the initial values as the present set values.
3. When the SET button is pressed, the selected operation will be performed and it will
return to the item setting screen.
When the MENU button is pressed, no operation will be performed and it will return
to the item setting screen.
Item contents
Item contents
and
"
"
" button and move the cursor to the desired
values.
(When SAVE operation has not been performed, the initial
values will be loaded.)
Item contents
and
"
"
" button and move the cursor to the desired
values.
(When SAVE operation has not been performed,
the initial values will be loaded.)
INF-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvcpro aj-ya455pDvcpro aj-yad455pDvcpro aj-cs455p

Table of Contents